Removal/Installation of Major Assemblies -

Fusion Ion

Touchscreen Removal

1. Turn off and unplug the game.

2. Unlock and open the bezel.

3. Remove the 6 thumbnuts fastening the bezel to the game.  See Figure 1.

4. Loosen the bezel only enough to gain access to the wire connections underneath, then disconnect

the button controller wire connection at the foot of the bezel.

5. Proceed to the top of the bezel and remove the dongle socket wire and ground wire.  See Figure 2.

Also remove the wire connection to the coin mechanism on the opposite side of the bezel.

6. Remove the bezel.

7. Remove the tie wraps securing the wire harnesses to the back of the monitor.  Disconnect the

VGA monitor cable connection and ground wire.  See Figure 1.

8. Disconnect the LCD connector and remove the OSD cable connection from the monitor.  See

Figure 1.

9. Remove the tie wrap around the touchscreen controller and disconnect the touchscreen controller

cable.  See Figure 1.   Also disconnect the Molex connector (orange and gray wires).

10.  Use dental floss to carefully cut the foam tape holding the touchscreen to the monitor until you are

able to completely remove the screen.  Once the touchscreen is completely free from the monitor,
remove any residual foam tape from the monitor with denatured alcohol.

Touchscreen  Installation

1. Clean the glass on the reverse side of the new or existing touchscreen with the supplied alcohol

wipe, then cut pieces of the supplied 1/2” foam tape long enough to cover each edge of the monitor
without overlapping.  After the tape is in place on the monitor, peel off the backing.  Carefully place
the touchscreen over the monitor in the same manner it was attached to the old monitor, making
sure the screen is properly and evenly aligned over the glass.  Clean the front of the touchscreen
with the supplied alcohol wipe once it is in place.

2. Lift the bezel to access the reverse side of the monitor.  Connect the touchscreen controller cable

to the touchscreen controller, then connect the Molex connector (orange and gray wires).  See
Figure 1.

3.   Restore the OSD cable and the VGA monitor cable to the back of the monitor.  Also reconnect the

VGA monitor cable ground wire.  See Figure 1.

4. Reconnect the LCD power connector (black and yellow wires).  See Figure 1.

5. Return the bezel in place on top of the game, but do not secure it.  Reconnect all wire connections

attached to the bezel, including the dongle socket wire, ground wire (see Figure 2), coin mecha-
nism and button controller connections.

6.   Secure the bezel completely by fastening the 6 existing thumbnuts.  See Figure 1.

7.   Plug in and turn on the game.

8.   When the game is finished booting, press the CALIBRATE button.

9.   Close and lock the bezel, then calibrate the touchscreen.

Troubleshooting Information - Removal/Installation of Major Assemblies -

Fusion Ion

manuals/manuals_Support_Center_Ion_20Fusion_IonTouchscreen_Fusion_pdf-html.html
background image

COPYRIGHT © 2005 MERIT INDUSTRIES, INC.

Troubleshooting Information - Removal/Installation of Major Assemblies -

Fusion Ion

                                   

 

LCD POWER 
CONNECTOR 

THUMBNUTS 
(6 PLACES) 

OSD CABLE 
CONNECTION 

VGA MONITOR CABLE 

GROUND 
WIRES 

TOUCHSCREEN 
CONTROLLER CABLE 

TOUCHSCREEN CONTROLLER 

FIGURE 1 - REAR VIEW OF MONITOR / UNDERSIDE OF BEZEL

                             

 

DONGLE 
SOCKET 

GROUND 
WIRE 

FIGURE 2 - DONGLE SOCKET AND GROUND WIRE CONNECTIONS